Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 297-302, 2022.
Article in Chinese | WPRIM | ID: wpr-932601

ABSTRACT

Objective:To investigate the differences in applicability of both the portable high-purity germanium (HPGe) γ spectrometer and the portable lanthanum bromide (LaBr) γ spectrometer for measuring thyroid 131I activity and internal exposure monitoring for radiation workers. Method:Both DETECTIVE-DX100-KT portable HPGe γ spectrometer and InSpector 1000 portable LaBr γ spectrometer were used to measure the 131I content in thyroid of radiation workers for comparison of the measuring result, minimum detectable activity (MDA) and corresponding annual committed effective doses between two types of spectrometers. Results:The detection rate of 131I in thyroid of radiation workers was 67.7% for HPGe γ spectrometer and 26.2% for LaBr γ spectrometer, respectively. The MDA was 12.26-14.74 Bq (measuring time: 3-5 min) for HPGe γ spectrometer and 56.56-80.37 Bq for LaBr γ spectrometer (measuring time: 2-4 min). The annual committed effective dose corresponding to MDA was 0.07-0.08 mSv (3-5 min) for HPGe and 0.31-0.45 mSv (2-4 min) for LaBr, respectively, in the case of using chronic continuous intake mode and 7 d monitoring period. Conclusions:The minimum detectable activity (MDA) of the two types of portable spectrometers could meet the requirements specified in GBZ 129-2016 Specifications for individual monitoring of occupational internal exposure for thyroid monitoring equipment. The two types of spectrometers could be used for routine monitoring of internal contamination. The difference between the monitoring result of LaBr γ and HPGe γ spectrometers might be due to such factors as large uncertainty in short measuring time and low activity concentrations, incomplete identical of distance between probe and neck, probe angle setting, different response of equipment to the environment, background deduction method.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 448-450, 2018.
Article in Chinese | WPRIM | ID: wpr-708086

ABSTRACT

Objective To analyze the specific activity of radionuclides based on laboratory intercomparison.Methods Intercomparison of the measurements of radioanuclides 232Th,40K and 137Cs in soil samples,organized by National Institute for Radiological Protection,China CDC,was conducted using HPGe γ-spectrometry and the method of relative comparison and efficiency curve,respectively.Results The relative deviations were all less than 5%compared to the reference values in the conditions of both relative comparison method and efficiency curve method used,respectively.The relative deviations to the reference values were less than 4%for the relative comparison method.Conclusions Both the relative comparison method and the efficiency curve method can be used to measure the activity of radionuclides in the intercomparison samples,and the latter is superior to the former.

SELECTION OF CITATIONS
SEARCH DETAIL